    Specifications


    rangeTeSys
    TeSys Deca
    product nameTeSys D
    TeSys Deca
    product or component typeContactor
    device short nameLC1D
    contactor applicationResistive load
    Motor control
    utilisation categoryAC-4
    AC-1
    AC-3
    AC-3e
    poles description3P
    power pole contact composition3 NO
    [Ue] rated operational voltagePower circuit: <= 690 V AC 25...400 Hz
    Power circuit: <= 300 V DC
    [Ie] rated operational current60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
    40 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
    40 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
    motor power kW18.5 kW at 380...400 V AC 50/60 Hz (AC-3)
    11 kW at 220...230 V AC 50/60 Hz (AC-3)
    22 kW at 415...440 V AC 50/60 Hz (AC-3)
    22 kW at 500 V AC 50/60 Hz (AC-3)
    30 kW at 660...690 V AC 50/60 Hz (AC-3)
    9 kW at 400 V AC 50/60 Hz (AC-4)
    18.5 kW at 380...400 V AC 50/60 Hz (AC-3e)
    11 kW at 220...230 V AC 50/60 Hz (AC-3e)
    22 kW at 415...440 V AC 50/60 Hz (AC-3e)
    22 kW at 500 V AC 50/60 Hz (AC-3e)
    30 kW at 660...690 V AC 50/60 Hz (AC-3e)
    motor power HP (UL / CSA)5 hp at 230/240 V AC 50/60 Hz for 1 phase motors
    10 hp at 230/240 V AC 50/60 Hz for 3 phases motors
    30 hp at 575/600 V AC 50/60 Hz for 3 phases motors
    10 hp at 200/208 V AC 50/60 Hz for 3 phases motors
    3 hp at 115 V AC 50/60 Hz for 1 phase motors
    30 hp at 460/480 V AC 50/60 Hz for 3 phases motors
    control circuit typeAC at 50/60 Hz
    [Uc] control circuit voltage220 V AC 50/60 Hz
    auxiliary contact composition1 NO + 1 NC
    [Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947
    overvoltage categoryIII
    [Ith] conventional free air thermal current10 A (at 60 °C) for signalling circuit
    60 A (at 60 °C) for power circuit
    Irms rated making capacity140 A AC for signalling circuit conforming to IEC 60947-5-1
    250 A DC for signalling circuit conforming to IEC 60947-5-1
    800 A at 440 V for power circuit conforming to IEC 60947
    rated breaking capacity800 A at 440 V for power circuit conforming to IEC 60947
    [Icw] rated short-time withstand current320 A 40 °C - 10 s for power circuit
    720 A 40 °C - 1 s for power circuit
    72 A 40 °C - 10 min for power circuit
    165 A 40 °C - 1 min for power circuit
    100 A - 1 s for signalling circuit
    120 A - 500 ms for signalling circuit
    140 A - 100 ms for signalling circuit
    associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1
    80 A gG at <= 690 V coordination type 1 for power circuit
    80 A gG at <= 690 V coordination type 2 for power circuit
    average impedance1.5 mOhm - Ith 60 A 50 Hz for power circuit
    [Ui] rated insulation voltagePower circuit: 600 V CSA certified
    Power circuit: 600 V UL certified
    Signalling circuit: 690 V conforming to IEC 60947-1
    Signalling circuit: 600 V CSA certified
    Signalling circuit: 600 V UL certified
    Power circuit: 690 V conforming to IEC 60947-4-1
    electrical durability1.4 Mcycles 60 A AC-1 at Ue <= 440 V
    1.5 Mcycles 40 A AC-3 at Ue <= 440 V
    1.5 Mcycles 40 A AC-3e at Ue <= 440 V
    power dissipation per pole2.4 W AC-3
    5.4 W AC-1
    2.4 W AC-3e
    Front coverWith
    mounting supportPlate
    Rail
    standardsCSA C22.2 No 14
    EN 60947-4-1
    EN 60947-5-1
    IEC 60947-4-1
    IEC 60947-5-1
    UL 508
    IEC 60335-1
    product certificationsCCC
    GOST
    UL
    CSA
    connections - terminalsControl circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
    Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
    Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
    Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
    Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
    Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
    Power circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm²flexible without cable end
    Power circuit: EverLink BTR screw connectors 2 cable(s) 1…25 mm²flexible without cable end
    Power circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm²flexible with cable end
    Power circuit: EverLink BTR screw connectors 2 cable(s) 1…25 mm²flexible with cable end
    Power circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm²solid without cable end
    Power circuit: EverLink BTR screw connectors 2 cable(s) 1…25 mm²solid without cable end
    tightening torqueControl circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
    Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
    Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25…35 mm² hexagonal screw head 4 mm
    Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1…25 mm² hexagonal screw head 4 mm
    Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
    Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
    operating time4...19 ms opening
    12...26 ms closing
    safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
    B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
    mechanical durability6 Mcycles
    maximum operating rate3600 cyc/h 60 °C
    Complementary
    coil technologyWithout built-in suppressor module
    control circuit voltage limits0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
    0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz
    0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz
    1...1.1 Uc (60…70 °C):operational AC 50/60 Hz
    inrush power in VA140 VA 60 Hz cos phi 0.75 (at 20 °C)
    160 VA 50 Hz cos phi 0.75 (at 20 °C)
    hold-in power consumption in VA13 VA 60 Hz cos phi 0.3 (at 20 °C)
    15 VA 50 Hz cos phi 0.3 (at 20 °C)
    heat dissipation4…5 W at 50/60 Hz
    auxiliary contacts typeType mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
    type mirror contact 1 NC conforming to IEC 60947-4-1
    signalling circuit frequency25...400 Hz
    minimum switching current5 mA for signalling circuit
    minimum switching voltage17 V for signalling circuit
    non-overlap time1.5 ms on de-energisation between NC and NO contact
    1.5 ms on energisation between NC and NO contact
    insulation resistance> 10 MOhm for signalling circuit
    Environment
    IP degree of protectionIP20 front face conforming to IEC 60529
    climatic withstandConforming to IACS E10
    conforming to IEC 60947-1 Annex Q category D
    protective treatmentTH conforming to IEC 60068-2-30
    pollution degree3
    ambient air temperature for operation-40…60 °C
    60…70 °C with derating
    ambient air temperature for storage-60…80 °C
    operating altitude0...3000 m
    fire resistance850 °C conforming to IEC 60695-2-1
    mechanical robustnessVibrations contactor open: 2 Gn, 5...300 Hz
    Vibrations contactor closed: 4 Gn, 5...300 Hz
    Shocks contactor closed: 15 Gn for 11 ms
    Shocks contactor open: 10 Gn for 11 ms
    height122 mm
    width55 mm
    depth120 mm
    net weight0.85 kg